Home »
Products »
PPE, Safety & Test »
Test & Measurement »
Bench Power Supplies & Sources »
Source Meters »
1 to
40 of
42 Items
- Source Meters
Page 1 of 2
Brand |
: |
RS PRO |
MFR # |
: |
260-2861 |
Series |
: |
RSSM |
Source Meter Function |
: |
Voltage Source, Current Source, Voltmeter, Ammeter, Ohmmeter |
Number of Channels |
: |
4 |
Source Voltage Range |
: |
21 → 210 V |
Output Power |
: |
22 W |
|
Brand |
: |
Keithley |
MFR # |
: |
2657A |
Series |
: |
2600 |
Source Meter Function |
: |
High Power, High Voltage, Low Current |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
3000 V |
Source Current Range |
: |
20 mA |
Output Power |
: |
180 W |
|
Brand |
: |
Keithley |
MFR # |
: |
2790-H |
Series |
: |
2790 |
Source Meter Function |
: |
Low Current And High Voltage |
Source Voltage Range |
: |
1000 V |
Source Current Range |
: |
3 A |
|
Brand |
: |
Keithley |
MFR # |
: |
2790-H/E |
Series |
: |
2790 |
Source Meter Function |
: |
Low Current And High Voltage |
Source Voltage Range |
: |
1000 V |
Source Current Range |
: |
3 A |
|
Brand |
: |
Keithley |
MFR # |
: |
6220/2182A/E |
Series |
: |
6220 |
Source Meter Function |
: |
DC Current Source |
Source Voltage Range |
: |
220 V |
Source Current Range |
: |
100 mA |
|
Brand |
: |
Keithley |
MFR # |
: |
6220 |
Series |
: |
6220 |
Source Meter Function |
: |
AC And DC Current Source |
Source Voltage Range |
: |
220 V |
Source Current Range |
: |
210 mA |
|
Brand |
: |
Keithley |
MFR # |
: |
6221/2182A/E |
Series |
: |
6220 |
Source Meter Function |
: |
AC And DC Current Source |
Source Voltage Range |
: |
220 V |
Source Current Range |
: |
210 mA |
|
Brand |
: |
Aim-TTi |
MFR # |
: |
SMU4201 |
Series |
: |
SMU4000 |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
10nV → 200V |
Source Current Range |
: |
100fA → 3A |
Output Power |
: |
25W |
Resistance Measurement Range |
: |
1μ? to 10G |
|
Brand |
: |
Aim-TTi |
MFR # |
: |
SMU4001 |
Series |
: |
SMU4000 |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
10nV → 20v |
Source Current Range |
: |
100fA → 3A |
Output Power |
: |
25W |
Resistance Measurement Range |
: |
1μ? to 10G |
|
Brand |
: |
Keithley |
MFR # |
: |
6430 |
Series |
: |
Keithley |
Source Meter Function |
: |
Voltage And Current |
Source Voltage Range |
: |
200 V |
Source Current Range |
: |
100 mA |
Output Power |
: |
2.2 W |
|
Brand |
: |
Tempo Kingfisher |
MFR # |
: |
T2803 |
Series |
: |
KI 2800 |
Source Meter Function |
: |
Handheld Optical Light Source |
Output Power |
: |
-20 dBm |
|
Brand |
: |
Tempo Kingfisher |
MFR # |
: |
T28010-APC |
Series |
: |
KI 2800 |
Source Meter Function |
: |
Handheld Optical Light Source |
Output Power |
: |
-3 dBm |
|
Brand |
: |
Tempo Kingfisher |
MFR # |
: |
T2824 |
Series |
: |
KI 2800 |
Source Meter Function |
: |
Handheld Optical Light Source |
Output Power |
: |
0 dBm |
|
Brand |
: |
Tempo Kingfisher |
MFR # |
: |
T2822 |
Series |
: |
KI 2800 |
Source Meter Function |
: |
Handheld Optical Light Source |
Output Power |
: |
0 dBm |
|
Brand |
: |
Tempo Kingfisher |
MFR # |
: |
T9812A |
Series |
: |
KI 9800 |
Source Meter Function |
: |
Optical Light Source |
Output Power |
: |
-20 dBm |
|
Brand |
: |
Tempo Kingfisher |
MFR # |
: |
T9822A |
Series |
: |
KI 9800 |
Source Meter Function |
: |
Optical Light Source |
Output Power |
: |
0 dBm |
|
Brand |
: |
Keithley |
MFR # |
: |
2470 |
Series |
: |
2400 |
Source Meter Function |
: |
Current, Resistance, Voltage |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
200 mV → 1000 V |
Source Current Range |
: |
10 nA → 1 A |
Output Power |
: |
20 W |
Resistance Measurement Range |
: |
2 Ω → 200 MΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2651A |
Series |
: |
2600 |
Source Meter Function |
: |
Current Voltage Source, DMM, Electronic Load, Power Supply, Waveform Generator |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
±100 mV → ±40 V |
Source Current Range |
: |
±100 nA → ±50 A |
Output Power |
: |
2000 W |
|
Brand |
: |
Keithley |
MFR # |
: |
2604B |
Series |
: |
2600 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
2 |
Source Voltage Range |
: |
±100 mV → ±40 V |
Source Current Range |
: |
±100 nA → ±10 A |
Output Power |
: |
40 W |
Resistance Measurement Range |
: |
500 nΩ → 40 TΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2614B |
Series |
: |
2600 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
2 |
Source Voltage Range |
: |
±200 mV → ±200 V |
Source Current Range |
: |
±100 nA → ±10 A |
Output Power |
: |
60 W |
Resistance Measurement Range |
: |
500 nΩ → 100 TΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2601B-Pulse |
Series |
: |
2601B |
Source Meter Function |
: |
Pulser, Source Measure Unit |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
100 mV → 40 V |
Source Current Range |
: |
100 nA - 10 A |
Output Power |
: |
40.4 W |
Resistance Measurement Range |
: |
0.5 Ω → 100 Ω, SMU : 1 kΩ |
|
Brand |
: |
Rohde & Schwarz |
MFR # |
: |
NGU401-G |
Bench Power Supply Type |
: |
Source Measure Unit |
Output Current |
: |
3 A, 8 A |
Series |
: |
NGU |
Number of Outputs |
: |
1 |
Power Rating |
: |
60W |
Model Number |
: |
NGU401-G |
|
Brand |
: |
Rohde & Schwarz |
MFR # |
: |
NGU401COM |
Bench Power Supply Type |
: |
Source Measure Unit |
Output Current |
: |
3 A, 8 A |
Series |
: |
NGU |
Number of Outputs |
: |
1 |
Power Rating |
: |
60W |
Model Number |
: |
NGU401COM |
|
Brand |
: |
Rohde & Schwarz |
MFR # |
: |
NGU201-P |
Series |
: |
NGU |
Calibrated |
: |
UKAS |
|
Brand |
: |
Rohde & Schwarz |
MFR # |
: |
NGU401-P |
Output Current |
: |
3 A, 8 A |
Series |
: |
NGU |
Number of Outputs |
: |
1 |
Power Rating |
: |
60W |
Calibrated |
: |
UKAS |
Model Number |
: |
NGU401-P |
|
Brand |
: |
Rohde & Schwarz |
MFR # |
: |
NGU201COM |
Series |
: |
NGU |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
0 → 20 V |
Source Current Range |
: |
8 A |
Output Power |
: |
60 W |
Resistance Measurement Range |
: |
0 → 10 kΩ |
|
Brand |
: |
Rohde & Schwarz |
MFR # |
: |
NGU201-G |
Series |
: |
NGU |
Source Meter Function |
: |
Current Resistance Voltage Measure |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
0 → 20 V |
Source Current Range |
: |
10uA → 10A |
Output Power |
: |
60 W |
Resistance Measurement Range |
: |
0 → 10 kΩ |
Model Number |
: |
NGU201-G |
|
Brand |
: |
Keithley |
MFR # |
: |
2401. |
Series |
: |
2400 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
±200 mV → ±20 V |
Source Current Range |
: |
±1 μA → ±1 A |
Output Power |
: |
20 W |
Resistance Measurement Range |
: |
200 mΩ → 200 MΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2461 |
Series |
: |
2400 |
Source Meter Function |
: |
Current, Resistance, Voltage |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
200 mV → 100 V |
Source Current Range |
: |
10 (Pulsed Output) A, 7 (DC Output) A |
Output Power |
: |
1000 W |
Resistance Measurement Range |
: |
2 Ω → 200 MΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2601B |
Series |
: |
2600 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
±100 mV → ±40 V |
Source Current Range |
: |
±100 nA → ±10 A |
Output Power |
: |
40 W |
Resistance Measurement Range |
: |
50 nΩ → 40 TΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2612B |
Series |
: |
2600 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
2 |
Source Voltage Range |
: |
±200 mV → ±200 V |
Source Current Range |
: |
±100 nA → ±10 A |
Output Power |
: |
60 W |
Resistance Measurement Range |
: |
500 nΩ → 100 TΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
6221 |
Bench Power Supply Type |
: |
AC/DC Power Source |
Output Current |
: |
4 pA → 210mA |
Series |
: |
6221 |
Number of Outputs |
: |
4 |
Power Rating |
: |
11W |
Model Number |
: |
6221 |
|
Brand |
: |
Keithley |
MFR # |
: |
2450 |
Series |
: |
2400 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
±20 mV → ±200 V |
Source Current Range |
: |
±10 nA → ±1 A |
Output Power |
: |
20 W |
Resistance Measurement Range |
: |
20 Ω → 200 MΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2400 |
Series |
: |
2400 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
±200 mV → ±200 V |
Source Current Range |
: |
±1 μA → ±1 A |
Output Power |
: |
20 W |
Resistance Measurement Range |
: |
200 mΩ → 200 MΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2410. |
Series |
: |
2400 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
±200 mV → ±1000 V |
Source Current Range |
: |
±1 μA → ±1 A |
Output Power |
: |
20 W |
Resistance Measurement Range |
: |
200 mΩ → 200 MΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2460 |
Series |
: |
2460 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
200mV → 100V |
Source Current Range |
: |
1μA → 7A |
Output Power |
: |
100 W |
Resistance Measurement Range |
: |
2 Ω → 20 MΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2602B |
Series |
: |
2600 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
2 |
Source Voltage Range |
: |
±100 mV → ±40 V |
Source Current Range |
: |
±100 nA → ±10 A |
Output Power |
: |
80 W |
Resistance Measurement Range |
: |
500 nΩ → 40 TΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2636B |
Series |
: |
2600 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
2 |
Source Voltage Range |
: |
±200 mV → 200 V |
Source Current Range |
: |
±100 pA → 1.5 A |
Output Power |
: |
60 W |
Resistance Measurement Range |
: |
50 nΩ → 10 pΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2611B |
Series |
: |
2600 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
±200 mV → ±200 V |
Source Current Range |
: |
±100 nA → ±10 A |
Output Power |
: |
30 W |
Resistance Measurement Range |
: |
500 nΩ → 100 TΩ |
|
Brand |
: |
Keithley |
MFR # |
: |
2635B |
Series |
: |
2600 |
Source Meter Function |
: |
Current Resistance Voltage Measure, Current Voltage Source |
Number of Channels |
: |
1 |
Source Voltage Range |
: |
±200 mV → ±200 V |
Source Current Range |
: |
±100 nA → ±10 A |
Output Power |
: |
60 W |
Resistance Measurement Range |
: |
500 nΩ → 100 TΩ |
|